DIATON Tonometer for IOP Measurement

£995.00 (Delivered)

Reference: OMP12043 Age: Brand New Location: none-uk

DIATON Tonometer for IOP Measurement

Pen-like non-contact tonometer for IOP measuring!

Diaton tonometer is a handheld device that measures IOP through the eyelid & completely satisfies present-day requirements of diagnostic equipment.

Spheres of diaton tonometer application
ophthalmology (including children's)
general medical practice
optometry
neurology
Method for measuring the intraocular pressure through the eyelid and the device realizing this method are protected by the Patent of Russia № 2123798, United States Patent № US 6,394,954 �’1 and Patent of Japan №3593314.

Nowadays transpalpebral scleral tonometry has no other alternative in the world. It is the most favourable method to carry out preclinical medical research of the population and , moreover,it works in such complicated clinical cases when it is impossible to use classical tonometry methods. Diaton is a helpful tool for ophthalmologists faced with pediatric patients or who have corneal abnormalities such as corneal edema, erosions or keratoprosthesis.
Approved by the FDA in 2006, the instrument has been the subject of numerous clinical trials, where it has been found to be comparable with the gold standard, the Goldmann tonometer, and with many other devices.

Innovative approach to IOP measurement opens up wide medical opportunities and indisputable benefits both for doctors & patients:

for doctors:
Accurate results
Wide range of medical opportunities
Quick & efficient procedure of measuring (IOP measurement takes several seconds)
Сreates an image of a modern doctor working in an up-to-date equipped medical center
Wide medical opportunities
Low dispensable materials' expenses

for patients:
No contact to the cornea
No risk of infection
No anesthesia drops
No pain
No need to take out contacts


Transpalpebral "diaton" tonometer is effective and irreplaceable in complicated medical cases:
Can measure IOP even in the presence of viral infections, allergic reactions, dry eye syndrome, contraindications for corneal tonometry
Can serve as non-invasive day monitoring tool while selecting the adequate hypotensive medical treatment
Can measure IOP on patients after corneal surgeries
Сan measure IOP with contact lenses on
Can measure IOP on immobilized patients
Screening tool for elevated IOP by PCPs
Trained family members can monitor IOPs of glaucoma patients at home

Comparative tests of diaton tonometer and Goldman tonometer give the evidence of high reliability that diaton tonometer guarantees.
SPECIFICATIONS

Measurement range, mm Hg 5-60
Measurement error Limit of the admissible measurement error in the range, not more:
from 5 to 20 mm Hg - ±2 mm Hg;
from 20 to 60 mm Hg - ±10%
The time of a single measurement, s, not more 3
Supply voltage, V 3
Number of measurements using one battery set, not less 1500
Service life, not less 5
Weight, g 89
Dimensions, mm, not more 174 х 26 х 20